<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-14 08-19-27
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 71 kHz 15323 14,6185
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,9 dBr 5,12 dBr 7,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 71 kHz MIN: 10 kHz % above 76 kHz: 14,6185 Acquired: 2026.09.14 8.18.24 Total samples: 15323 Equivalent time: 0:12:46 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 7,0 dBr MIN: 3,9 dBr AVE: 5,12 dBr % above 12,2 dBr: 0,0 Last value: 4,8 dBr (2026.09.14 8.18.23) 08.04 08.06 08.08 08.10 08.12 08.14 08.16 08.18 0 2 4 6 8 Pm [dBr]